| 1. | Disconnect high voltage power to condenser. |
| 2. | Remove side covers and top to access condenser coil inside and out. |
| 3. | Remove debris around and inside condenser and vacuum if necessary. |
| 4. | Hose off loose dirt on condensing coil. |
| 5. | Apply biodegradable coil cleaner to condensing coil and let soak. |
| 6. | Thoroughly rinse off coil cleaner. |
| 7. | Clear condenser drain holes. |
| 8. | Check wire connections for compressor and replace connector if necessary. |
| 9. | Check condition of crank case heater. |
| 10. | Oil condenser fan motor. |
| 11. | Check and tighten condenser fan motor mounting bracket. |
| 12. | Clean condenser fan blade. |
| 13. | Check condenser fan blade for cracks in metal. |
| 14. | Tighten fan blade set screw. |
| 15. | Open and clean debris out of electrical compartment. |
| 16. | Visually inspect all wiring for wear or breaks. |
| 17. | Repair small wiring problems in electrical compartment if necessary.
(Large electrical problems such as burnt or corroded wires or
components repaired at extra charge). |
| 18. | Check compressor contactor operation and look for burnt points or
corroded connectors and replace contactor if necessary at extra
charge and with homeowners approval. |
| 19. | Reassemble condenser. |
| 20. | Service indoor blower assembly, clean squirrel cage and housing. |
| 21. | Oil indoor blower motor. |
| 22. | If accessible brush and vacuum evaporator coil. |
| 23. | Apply self rinsing evaporator coil cleaner. |
| 24. | Replace disposable air filter or clean washable air filters-extra
charge for Aprilaire of Air Bear air filters. |
| 25. | Check thermostat operation and set to cool home. |
| 26. | Turn on air handler, look and listen for unusual vibrations or noise. |
| 27. | Check amperage of blower motor and compare to manufacturers
rating plate. |
| 28. | Fire up condenser, look and listen for unusual vibrations or noises. |
| 29. | Check compressor amperage and compare to manufacturers rating. |
| 30. | Check low and high side pressures and analyze system operation. |
| 31. | Do superheat or subcool calculations to determine system freon
charge. |
| 32. | Add freon if necessary at extra charge and with approval. |